0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Autor(en):

Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Structural Engineering International, , n. 3, v. 5
Seite(n): 192-193
DOI: 10.2749/101686695780601024
Abstrakt:

A single-storey warehouse hall 70 x 30 m in plan and about 12 m high with internal built-in structures was under construction when it collapsed. Its principal load-bearing structure consisted of reinforced concrete columns, steel primary beams and reinforced concrete and steel diaphragms with steel roof trusses. The collapse of the steel warehouse roof caused considerable material damage as well as some injuries. Disregarding the unprofessional performance of the producer of the steel elements, the contribution of the structural designer to this failure was clear. The structural analysis of the steel truss and the assessment of maximum computed stresses were sound. However, the analytical model did not correspond with the actual structural behaviour. Also the 4 mm fillet welds used for welding the steel box of the lower chord, having a direct casual relation to the collapse, had not been numerically analyzed and assessed at all.

Bauwerkstypen

  • Über diese
    Datenseite
  • Reference-ID
    10003610
  • Veröffentlicht am:
    19.09.2002
  • Geändert am:
    28.10.2016
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine