0
  • DE
  • EN
  • FR
  • Internationale Datenbank und Galerie für Ingenieurbauwerke

Anzeige

Research on the Seismic Performance of Prefabricated Bridge Piers Using UHPC Grout under an Eccentric Load

Autor(en): ORCID

ORCID

Medium: Fachartikel
Sprache(n): Englisch
Veröffentlicht in: Advances in Civil Engineering, , v. 2023
Seite(n): 1-11
DOI: 10.1155/2023/9092697
Abstrakt:

At present, research on prefabricated piers is limited to the axial compression state. However, many piers are under small eccentric compression in practical engineering. In this article, the seismic performance of ultrahigh performance concrete (UHPC)-grouted corrugated pipe-connected piers under small eccentric compression was studied. A pseudostatic test was carried out by using a prefabricated pier column model connected with UHPC-grouted corrugated pipes. The failure mechanism of the plastic hinge area of the column base was studied, and the failure mode, energy dissipation capacity, displacement ductility, and ultimate bearing capacity were compared with those of an ordinary axially compressed pier column structure. The result shows that compared to the conventional cast-in-place(CIP) pier, the overall energy dissipation capacity and the ductility factor of assembled pier with UHPC-grouted corrugated pipe-connection were decreased approximately by 5.0% and by 10%, respectively. The pinching phenomenon of the hysteresis curve of the precast pier was more obvious. When the assembled piers were under small eccentric compression, the overall energy dissipation capacity was close to that of conventional CIP piers and the ductility factor was improved by 20%. Comparison of two precast piers using the same UHPC grout connections shows that the stiffness degradation process of precast pier under small eccentric compression was similar to that under axial compression. But the ductility coefficient of precast pier under small eccentric compression increased by about 20%. The small eccentric compression caused different damage degrees in the plastic hinge zone at the bottom of the precast column. The ultimate load in the same direction as the additional bending moment was 55% lower than that of the opposite direction.

Copyright: © Ben Zeng et al. et al.
Lizenz:

Dieses Werk wurde unter der Creative-Commons-Lizenz Namensnennung 4.0 International (CC-BY 4.0) veröffentlicht und darf unter den Lizenzbedinungen vervielfältigt, verbreitet, öffentlich zugänglich gemacht, sowie abgewandelt und bearbeitet werden. Dabei muss der Urheber bzw. Rechteinhaber genannt und die Lizenzbedingungen eingehalten werden.

  • Über diese
    Datenseite
  • Reference-ID
    10710960
  • Veröffentlicht am:
    21.03.2023
  • Geändert am:
    10.05.2023
 
Structurae kooperiert mit
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine